SY/T 7397-2024 Technical specification for subsea pipeline connectors and jumpers English, Anglais, Englisch, Inglés, えいご
This is a draft translation for reference among interesting stakeholders. The finalized translation (passing through draft translation, self-check, revision and verification) will be delivered upon being ordered.
ICS
E
Professional standard of the People's Republic of China
SY/T 7397-2024
Technical specification for subsea pipeline connectors and jumpers
海底管道连接器和水下跨接管系统技术规范
(English Translation)
Issue date: 2024-09-24 Implementation date: 2025-03-24
Issued by National Development and Reform Commission, P.R.C
Contents
Foreword
1 Scope
2 Normative References
3 Terms and Definitions
4 Abbreviations
5 Design Conditions
5.1 Environmental Conditions
5.2 Design Cases
5.3 Vessel Parameters
6 Design Criteria
6.1 General Requirements
6.2 Design Life
6.3 SPM Location and Spatial Requirements
7 Design Requirements
7.1 Turret System
7.2 Mooring System
7.3 Mooring Foundation
7.4 Dynamic Risers and Umbilicals
8 Construction and Inspection
8.1 General Requirements
8.2 Construction Materials
8.3 Welding
8.4 Quality Control and Inspection
9 Offshore Installation
9.1 General Requirements
9.2 Installation of Mooring Foundation
9.3 Laying of Mooring Lines
9.4 Hook-up of Mooring Lines
Technical Specification for Subsea Pipeline Connectors and Subsea Jumper Systems
1 Scope
This document specifies the technical requirements for the design, verification of subsea pipeline connectors, as well as the selection, design analysis, prefabrication, assembly, testing, measurement, installation, and retrieval of subsea jumper systems.
This document applies to subsea pipeline connectors and jumpers used in subsea oil and gas production and injection services.
2 Normative References
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 21412.11 Petroleum and natural gas industries — Design and operation of subsea production systems — Part 11: Recommended practice for flexible pipe systems
SY/T 7056 Free spanning of submarine pipelines
SY/T 10037 Subsea pipeline systems
ISO 19901-1:2015 Petroleum and natural gas industries — Specific requirements for offshore structures — Part 1: Metocean design and operating considerations
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
connector system
An actuated connector and other related accessories used to achieve its function.
3.2
jumper
A pipeline connection structure used to tie-in pipeline ends, manifolds, or trees.
3.3
rigid jumper
A jumper constructed using rigid steel pipe.
3.4
flexible jumper
A jumper constructed using flexible pipe.
3.5
multibore connector
A connector with more than one bore for medium transmission. Bores may be concentric, symmetrical, or asymmetrical; internal media may be production and/or injection liquids or gases, hydraulic control fluid, corrosion inhibitors, etc.
3.6
integral connector
A connector that is locked and unlocked by means of an integral, non-removable actuator.
3.7
non-integral connector
A connector that is locked and unlocked by means of an external tool.
3.8
inboard hub
The hub attached to the tree or subsea structure pipe end.
3.9
outboard hub
The hub attached to the jumper or pig launcher/receiver, which mates with the inboard hub.
3.10
primary seal
The seal that acts as the initial barrier (or primary barrier) between the process fluid and the external environment.
3.11
secondary seal
A metal or elastomeric seal located between the inboard and outboard hub bodies, external to the primary seal.
3.12
contingency seal
A spare seal intended to replace the connector's primary metal seal.
3.13
lock
The action or state of fully engaging the connector with the inboard hub and achieving the full preload connection.
3.14
hub face separation
Separation at any circumferential position between the inboard and outboard hub faces caused by internal pressure, external loads, or a combination thereof.
3.15
park
The action of placing the jumper onto a subsea structure in an unconnected state.
3.16
preload
The clamping force applied to two interconnected parts to resist or counteract separation forces caused by internal pressure and/or external loads and bending moments.
3.17
flow induced vibration (FIV)
Vibration of a jumper caused by excitation from the internal fluid flow.
3.18
doghouses
Insulation structures, shaped like a "doghouse," encasing the connector.
4 Abbreviations
The following abbreviations apply to this document.
BOP: Blowout Preventer
FAT: Factory Acceptance Testing
MT: Magnetic Particle Testing
NCR: Nonconformance Report
NDT: Nondestructive Test
PT: Penetrant Testing
ROV: Remotely Operated Vehicle
RT: Radiographic Testing
RWP: Rated Working Pressure
UT: Ultrasonic Testing
5 System Selection